K31 Series relay protection tester secondary injection test equipment

Brand Name : KINGSINE

Model Number : K3163i

Certification : ISO9001,CE

Place of Origin : China

MOQ : 1 set

Payment Terms : T/T in advance,L/C

Supply Ability : 50 sets/month

Delivery Time : 15 working days

Contact Now

All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+4V analog channels output, Inbuilt

GPS and IRIG-B, and other advance functions.

◆ Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc

◆100/1000Mbit Fiber port for SMV and GOOSE simulations

◆6x35A & 4x310V independent high burden output channels

◆13 channels independent low-level signal outputs

◆ AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)

◆ Transducer calibration (0.02 class)

◆ Energy meter calibration (Mechanical & Electronic meters)

◆ Transient play back up to 3KHz

◆ Lightweight, <18Kg

◆ Fully function KRT software testing modules

◆ 3-Years guarantee of free repair and life-long maintenance

◆ Free software upgrade

Ordering Ref.

Model Current Outputs Voltage Outputs
K3166 6×35A @ 450VA max / 3×70A @ 850VA max 7×130V @ 75VA max
K3166i 6×35A @ 450VA max / 3×70A @ 850VA max 7×310V @ 90VA max
K3163 6×35A @ 450VA max / 3×70A @ 850VA max 4×130V @ 75VA max
K3163i 6×35A @ 450VA max / 3×70A @ 850VA max 4×310V @ 124VA max
K3130 3×35A @ 450VA max 4×130V @ 75VA max
K3130i 3×35A @ 450VA max 4×310V @ 124VA max

Able of what K31 series can test

Items ANSI® No.
IEC61850 numerical IEDs relay & merge unit
Distance protection relay 21
Synchronising or synchronism-check relays 25
Undervoltage relays 27
Directional Power relays 32
Undercurrent or underpower relays 37
Negative sequence overcurrent relays 46
Overcurrent/ground fault relays 50
Inverse time overcurrent/ground fault relays 51
Power factor relays 55
Overvoltage relays 59
Voltage or current balance relays 60
Directional overcurrent relays 67
Directional ground fault relays 67N
DC overcurrent relays 76
Phase-angle measuring or out-of-step protection relays 78
Automatic reclosing devices 79
Frequency relays 81
Motor overload protection relays 86
Differential protection relays 87
Directional voltage relays 91
Voltage and power directional relays 92
Tripping relays 94
Voltage regulating relays
Overimpedance relays, Z>
Underimpedance relays, Z
Time-delay relays

Characteristic

◆ 10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous

control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to

20x harmonics.

◆ Variable battery simulator, DC 0-350V, 140Watts max.

◆ 13 Low-level channels outputs up to 8Vac/10Vdc max.

◆ 0-600V / 0-5A AC/DC measurement in 0.1 class.

◆ Graphical test modules and templates for testing of various relays

◆ Quick relay testing facility in Manual mode

◆ Shot/Search/Check, Point & Click testing

◆ RIO/XRIO import & export facility

◆ Switch on to fault test(SOTF)

◆ Power system model for dynamic testing

◆ Inbuilt GPS and IRIG-B sync end-to-end testing

◆ Online Vector display

◆ Automatic test results assume

◆ Automatic test report creation

◆ Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection

Parameters

Voltage Outputs
Output Range & Power 4×310 V ac (L-N) 124 VA max each
2×620 V ac (L-L) 248 VA max each
3×350 V dc (L-N) 140 W max each
Accuracy

AC: <0.03%Rd+0.01Rg Typ.

<0.07%Rd+0.03Rg Guar.

DC: ±10mV @ <5V, ±0.5% @ ≥5V
Resolution 1mV
Distortion <0.05%Typ. / <0.1% Guar.
Current Outputs
Output Range & Power 6×35A ac (L-N) 450 VA max each
3×70A ac (2L-N) 850 VA max each
1×100A ac (6L-N) 1200 VA max
3×20A dc (L-N) 300W max each
Accuracy

AC: <0.05%Rd+0.02Rg Typ.

<0.15%Rd+0.05Rg Guar.

DC: ±5mA @ <1A, ±0.5% @ ≥1A
Resolution 1mA
Distortion <0.05%Typ. / <0.1% Guar.
13 Low-Level Channel Outputs
Quantity 13 Channels, 16 pin aviation socket
Voltage Outputs Range AC 0~8V, DC 0~10V
Current Outputs Range Nominal 2mA, 10mA max transient
Output Power ≥0.5VA
Accuracy

(0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar.

(0.8~8 Vrms): <0.02% Typ. / <0.05% Guar.

Resolution 0.25mV
Distortion(THD%) <0.05% Typ. / <0.1% Guar.
Frequency & Phase Angle
Frequency Range DC~1KHz, 3KHz transient
Frequency Accuracy ±1ppm
Frequency Resolution 0.001 Hz
Phase Range -360°~360°
Phase Accuracy <0.05° Typ. / <0.1° Guar. 50/60Hz
Phase Resolution 0.001°
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function)
Fiber Ports

2 x 100Base-FX Full Duplex, LC type

(Optional to 10/100Mbit, Ethernet RJ45 type)

Fiber Type 62.5/125um (Multiple optical fiber, Orange Red)
Wavelength 1310nm
Transmit Distance >1Km
Indicator

Spd Green(light): Valid connection

Link/Act Yellow(Blinking): Data exchanging

Note: All hardware of this module are ready for active
Aux. DC Voltage Source (Battery simulator)
Range 0~350V @ 140W max
Accuracy 0.5%Rg Guar.
Binary Input
Quantity 8pairs
Type wet/dry, measurement
Threshold 10~600Vdc or potential free, Programmable
Time resolution 100us
Debounce time 0~25ms (Software Controlled)
Time range Infinite
Time errors ±1ms @ 0.001~1s, ±0.1% @ >1s
Galvanic isolation 4 isolated with each 2 pairs
Binary Output (Relay Type)
Quantity 4pairs
Type

Potential free relay contacts, software controlled

Break Capacity AC Vmax: 400Vac / Imax:8A / Pmax:2500VA
Break Capacity DC Vmax: 300Vdc / Imax:5A / Pmax:150W
Binary Output (Semiconductor Type)
Quantity 4pairs
Type: Open-collector, 14 pin Aviation socket
Break Capacity DC

5~15Vdc / 5mA, 10mA max

AC not permit

Response time: 100us
Synchronization
Synchronization Mode 

GPS, SMA type antenna connector

IRIG-B, FT3

IEEE1588

Power supply & Environment
Nominal Input Voltage 100~240Vac
Permissible Input Voltage 85~264Vac, 125~350VDC
Nominal Frequency 50/60Hz
Permissible Frequency 45Hz~65Hz
Power Consumption 1500 VA max
Connection Type Standard AC socket 60320
Operating Temperature -10℃~55℃
Storage Temperature -20℃~70℃
Humidity <95%RH, non-condensing
Others
PC Connection RJ45 Ethernet, 10/100/1000M
Grounding Terminal 4mm banana socket
Weight 18 Kg
Dimensions(W x D x H) 468×375×164(mm)

Additional Information (Optional Modules)

DC Measurement Input (Transducer calibrator)
Voltage Input Range 0~±10V dc
Max Input ±11V dc
Accuracy <0.02% rg Typ. <0.05% rg Guar.
Input Impedance 1Mohm
Current Input Range 0~±1mA / 1~±20mA, auto range
Max Input 600mA
Accuracy <0.02% rg Typ. <0.05% rg Guar.
Input Impedance 15 ohm
AC/DC Measurement Input (Standard meter)
Input Quantity 8 channels (blend with binary input pairs)
Voltage range 0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V)
Voltage accuracy <0.1% Rg
Current range 0~5Arms(clamp input)
Current accuracy <0.1% Rg
Sample rate 10KHz
Input impedance 600KΩ
Frequency range 45~65Hz, Accuracy < 0.01Hz
Phase accuracy 0~360°, <0.2° Typ.
Transient Recorder
Input Quantity 8 input channels (blend with binary input pairs)
Recorder time Max 50 Sec.
Energy Meter Calibration
Sensor Usage Mechanical meters / Electronic meters
Sensor Output High lever:>4.5V, Low level:<0.2V
Pulse Input 1 pulse input port
Pulse Range 500KHz pulse input Max.
Pulse Output 1 Transistor output, Open-collector, 5-15Vdc/5mA


Product Tags:

protective relay tester

      

relay protection tester

      
Quality K31 Series relay protection tester secondary injection test equipment for sale

K31 Series relay protection tester secondary injection test equipment Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Kingsine Electric Automation Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0